Model VM500, General Purpose Industrial Display Monitor
Model VM500, General Purpose Industrial Display Monitor Model VM500 Outline Drawing
Made in the U.S.A.
Vibration Sensing Products

Model VM500
DISPLAY MONITOR FOR ACCELERATION, VELOCITY, DISPLACEMENT OR TEMPERATURE



Order Online Now!
Login/Register here to view ordering information.
Model VM500 Features:
  • Versatile Acceleration, Velocity, Displacement or Temperature Monitor
  • Interface with Accelerometer, Proximity Probe or "J" Type Thermocouple
  • Two Programmable Alarm Levels with Delay on Make/Break Relays
  • 4-20mA Scalable Output Interfacing w/PLC/DCS/Alarm/SCADA Systems
  • RMS (standard) or Peak Readings
  • Small NEMA 4, 1/8 DIN Package
  • High/Low Pass Filters Available
  • Adjustable Sampling Time
  • Signal Output: Raw, Filtered, Rep. DC Value
  • The Model VM500 display monitor offers incredible versatility and functionality in a small 1/8 DIN package, for an attractive price.

    It provides fully scalable 4-20 mA output for your control system, and also includes two form C relays for a variety of uses. The Model VM500 is available in displacement, velocity, acceleration and even temperature models for 10, 100, and 500 mV/g accelerometers and "J" type thermocouples.

    Some options include RMS or Peak display, as well as a wide range of high pass and low pass filters to focus on frequencies of interest.

    Applications:
    • Any Application where immediate display of machine PdM data or 4-20mA output is required.
    Operating Specifications

    Dynamic
    Accuracy ± 5%
    Acceleration Standard Configuration 3 Hz - 15 Hz
    Velocity Standard Configuration 3 Hz - 2 Hz
    Displacement Standard Configuration 3 Hz - 2 Hz
    High Pass Optional Filtering 3, 10, 50, 100, 500 kHz
    Low Pass Optional Filtering None, 50, 100, 500, 1k, 2k Hz
    Accelerometer Input 100 (standard) 10 or 500 mV/g
    Electrical
    Power Requirements, Auto-Sensing AC/DC 85-265 VAC (50-60 Hz), 95-370 VDC (standard), 15-48 VAC, 10-72 VDC
    Relays (2) Form C
    Environmental
    Operating Temperature Range 32 to 140°F / 0 to 60°C
    Acceleration Limit 20 g
    Velocity Limit 20 ips
    Displacement Limit 200 mils
    Thermocouple Temperature Limit 1400°F / 760°C
    Physical
    Display .56 inch Bright Red LED
    Weight 6.5 oz / 184 grams
    Front Panel NEMA-4
    Connectors MSTB
    Ordering Information
    VM500 X-XXX-X-HPXXXX-LPXXXX-X

    Standard Configurations:
    Standard configuration can be ordered with simply the one letter suffix and not the entire part number.
  • (1) VM500A
  • (2) VM500V
  • (3) VM500D


  • Accelerometer Input:
  • 010-10 mV/g
  • 100-100 mV/g (1)(2)(3)
  • 500-500 mV/g


  • Mode:
  • R-RMS (1)(2)
  • P-Peak (3)


  • Type:
  • A-Acceleration (1)
  • V-Velocity (2)
  • D-Displacement (3)
  • F-Temperature in F°
  • C-Temperature in C°


  • High Pass Filtering:
  • 0003-3 Hz (1)(2)(3)
  • 0010-10 Hz
  • 0050-50 Hz
  • 0100-100 Hz
  • 0500-500 Hz


  • Low Pass Filtering
  • 0000-None Hz (1)
  • 0050-50 Hz
  • 0100-100 Hz
  • 0500-500 Hz
  • 1000-1 kHz
  • 2000-2 kHz (2)(3)


  • Click here for Compatible Products and Accessories
  • For more information, please call us today at 1-609-716-4130.
    Model Number Prefix/Suffix Key (Click to Toggle)
    ACTMS - The ONLY available monitoring system for the detection and early warning of vane cracking!

    Visit the Pocket UT Microsite
    | More

    NEED ASSISTANCE?
    Call us at 1.609.716.4000
    INTERNATIONAL DIVISION
    ARG
    BHR
    BRA
    CAN
    CHN
    FRA
    GER
    GRE
    IND
    JPN
    MAS
    NED
    RUS
    SWE
    UK
    MISTRAS is Now an Award Winning Website!
    Engineering services are not being offered and will not be rendered where prohibited by law or where the company is not licensed to provide engineering services if a license is required.
    Copyright © 1995-2012 MISTRAS Group, Inc. All Rights Reserved.  |  Privacy  |  Terms of Use  |  Search  |  Problems or Comments? Send Feedback Feedback